Fedora10[ep18] ATOM330のCPU温度などをMuninで表示。

HDDの温度を追加したのでついでにCPUなども追加しちゃいましょう(^^)
muninでCPU温度などをグラフ化
http://d.hatena.ne.jp/halts/20090102/1230844335
参考ページを身ながらせっせと設定yumでlm_sensorsいれてセンサーディテクトかけてと。
# yum -y install lm_sensors
# sensors-detect

# sensors-detect
Stopping lm_sensors: [ OK ]
# sensors-detect revision 5249 (2008-05-11 22:56:25 +0200)
This program will help you determine which kernel modules you need
to load to use lm_sensors most effectively. It is generally safe
and recommended to accept the default answers to all questions,
unless you know what you’re doing.
We can start with probing for (PCI) I2C or SMBus adapters.
Do you want to probe now? (YES/no):
Probing for PCI bus adapters…
Use driver `i2c-i801′ for device 0000:00:1f.3: Intel 82801G ICH7
We will now try to load each adapter module in turn.
Load `i2c-i801′ (say NO if built into your kernel)? (YES/no):
Module loaded successfully.
If you have undetectable or unsupported I2C/SMBus adapters, you can have
them scanned by manually loading the modules before running this script.
We are now going to do the I2C/SMBus adapter probings. Some chips may
be double detected; we choose the one with the highest confidence
value in that case.
If you found that the adapter hung after probing a certain address,
you can specify that address to remain unprobed.
Next adapter: SMBus I801 adapter at 2000 (i2c-0)
Do you want to scan it? (YES/no/selectively):
Client found at address 0x2d
Probing for `Myson MTP008’… No
Probing for `National Semiconductor LM78’… No
Probing for `National Semiconductor LM78-J’… No
Probing for `National Semiconductor LM79’… No
Probing for `National Semiconductor LM80’… No
Probing for `National Semiconductor LM85 or LM96000’… No
Probing for `Analog Devices ADM1027, ADT7460 or ADT7463’… No
Probing for `SMSC EMC6D100, EMC6D101 or EMC6D102’… No
Probing for `Analog Devices ADT7476’… No
Probing for `Andigilog aSC7611’… No
Probing for `Andigilog aSC7621’… No
Probing for `National Semiconductor LM87’… No
Probing for `National Semiconductor LM93’… No
Probing for `Winbond W83781D’… No
Probing for `Winbond W83782D’… No
Probing for `Winbond W83783S’… No
Probing for `Winbond W83792D’… No
Probing for `Winbond W83793R/G’… No
Probing for `Winbond W83791SD’… No
Probing for `Winbond W83627HF’… No
Probing for `Winbond W83627EHF’… No
Probing for `Winbond W83627DHG’… No
Probing for `Asus AS99127F (rev.1)’… No
Probing for `Asus AS99127F (rev.2)’… No
Probing for `Asus ASB100 Bach’… No
Probing for `Winbond W83L784R/AR/G’… No
Probing for `Winbond W83L785R/G’… No
Probing for `Genesys Logic GL518SM Revision 0x00’… No
Probing for `Genesys Logic GL518SM Revision 0x80’… No
Probing for `Genesys Logic GL520SM’… No
Probing for `Genesys Logic GL525SM’… No
Probing for `Analog Devices ADM9240’… No
Probing for `Dallas Semiconductor DS1780’… No
Probing for `National Semiconductor LM81’… No
Probing for `Analog Devices ADM1026’… No
Probing for `Analog Devices ADM1025’… No
Probing for `Philips NE1619’… No
Probing for `Analog Devices ADM1029’… No
Probing for `Analog Devices ADM1030’… No
Probing for `Analog Devices ADM1031’… No
Probing for `Analog Devices ADM1022’… No
Probing for `Texas Instruments THMC50’… No
Probing for `VIA VT1211 (I2C)’… No
Probing for `ITE IT8712F’… No
Probing for `ALi M5879’… No
Probing for `SMSC LPC47M15x/192/292/997’… Success!
(confidence 6, driver `smsc47m192′)
Probing for `SMSC DME1737’… No
Probing for `SMSC SCH5027D-NW’… No
Probing for `Fintek F75373S/SG’… No
Probing for `Fintek F75375S/SP’… No
Probing for `Fintek F75387SG/RG’… No
Probing for `Analog Devices ADM1024’… No
Probing for `Winbond W83791D’… No
Client found at address 0x50
Probing for `Analog Devices ADM1033’… No
Probing for `Analog Devices ADM1034’… No
Probing for `SPD EEPROM’… Yes
(confidence 8, not a hardware monitoring chip)
Probing for `EDID EEPROM’… No
Some chips are also accessible through the ISA I/O ports. We have to
write to arbitrary I/O ports to probe them. This is usually safe though.
Yes, you do have ISA I/O ports even if you do not have any ISA slots!
Do you want to scan the ISA I/O ports? (YES/no):
Probing for `National Semiconductor LM78′ at 0x290… No
Probing for `National Semiconductor LM78-J’ at 0x290… No
Probing for `National Semiconductor LM79′ at 0x290… No
Probing for `Winbond W83781D’ at 0x290… No
Probing for `Winbond W83782D’ at 0x290… No
Probing for `IPMI BMC KCS’ at 0xca0… No
Probing for `IPMI BMC SMIC’ at 0xca8… No
Some Super I/O chips may also contain sensors. We have to write to
standard I/O ports to probe them. This is usually safe.
Do you want to scan for Super I/O sensors? (YES/no):
Probing for Super-I/O at 0x2e/0x2f
Trying family `National Semiconductor’… No
Trying family `SMSC’… Yes
Found `SMSC LPC47M15x/192/997 Super IO Fan Sensors’ Success!
(address 0x680, driver `smsc47m1′)
Probing for Super-I/O at 0x4e/0x4f
Trying family `National Semiconductor’… No
Trying family `SMSC’… No
Trying family `VIA/Winbond/Fintek’… No
Trying family `ITE’… No
Some south bridges, CPUs or memory controllers may also contain
embedded sensors. Do you want to scan for them? (YES/no):
Silicon Integrated Systems SIS5595… No
VIA VT82C686 Integrated Sensors… No
VIA VT8231 Integrated Sensors… No
AMD K8 thermal sensors… No
AMD K10 thermal sensors… No
Intel Core family thermal sensor… No
Intel AMB FB-DIMM thermal sensor… No
Now follows a summary of the probes I have just done.
Just press ENTER to continue:
Driver `smsc47m192′ (should be inserted):
Detects correctly:
* Bus `SMBus I801 adapter at 2000′
Busdriver `i2c-i801′, I2C address 0x2d
Chip `SMSC LPC47M15x/192/292/997′ (confidence: 6)
Driver `smsc47m1′ (should be inserted):
Detects correctly:
* ISA bus, address 0x680
Chip `SMSC LPC47M15x/192/997 Super IO Fan Sensors’ (confidence: 9)
Do you want to overwrite /etc/sysconfig/lm_sensors? (YES/no):
Starting lm_sensors: loading module i2c-i801 smsc47m192 sms[ OK ]
こんなんでましたけど~。
センサーが見つかったという事でOK^^;
Fedora11ではここがこけたので諦めましたw
# sensors
smsc47m192-i2c-0-2d
Adapter: SMBus I801 adapter at 2000
+2.5V: +2.54 V (min = +0.00 V, max = +3.32 V)
VCore: +1.15 V (min = +0.00 V, max = +2.99 V)
+3.3V: +3.39 V (min = +0.00 V, max = +4.38 V)
+5V: +5.13 V (min = +0.00 V, max = +6.64 V)
+12V: +12.19 V (min = +0.00 V, max = +15.94 V)
VCC: +3.39 V (min = +0.00 V, max = +4.38 V)
+1.5V: +1.58 V (min = +0.00 V, max = +1.99 V)
+1.8V: +1.78 V (min = +0.00 V, max = +2.39 V)
Chip Temp: +36.0°C (low = -127.0°C, high = +127.0°C)
CPU Temp: +47.0°C (low = +43.0°C, high = +50.0°C)
Sys Temp: +40.0°C (low = -127.0°C, high = +127.0°C)
cpu0_vid: +2.050 V
smsc47m1-isa-0680
Adapter: ISA adapter
fan1: 999 RPM (min = 1280 RPM, div = 4) ALARM
fan2: 4636 RPM (min = 1280 RPM, div = 4)

sensorsコマンドではこんな値が出ております。
4cmVGAファン12cmケースファンは静音タイプに換装済みっす。
夏モードでファンの回転数は少し高くしてあります^^;
こやつをグラフにって事ですね。
とりあえず全部のデータを残しておくべきか・・・
電源の様子も後で必要になりそうだからとりあえず入れておこう^^;
# ln -s /usr/share/munin/plugins/sensors_ /etc/munin/plugins/sensors_temp
# ln -s /usr/share/munin/plugins/sensors_ /etc/munin/plugins/sensors_fan
# ln -s /usr/share/munin/plugins/sensors_ /etc/munin/plugins/sensors_volt

“/etc/munin/plugin-conf.d/munin-node”に追加[sensors_*]
user root
リスタートservice munin-node restartで、5分待つと。
項目は出た。後はグラフですなぁ^^;
更に5分。出ましたヽ(*^。^*)ノ
(実はHDDも10分待てば出たのかも?w)

Fedora10[ep17] muninでSATA接続HDDの温度を表示してみる

何度か書いてますが、メモって事で(^◇^;
MRTGも一度設定すればシンプルで見やすいんですけどねぇw
MRTGよりお手軽に負荷やトラフィックをグラフ化できる「Munin」
http://gigazine.net/index.php?/news/comments/20060904_munin/
Muninをカスタマイズして表示されるグラフの種類を増やしてみる
http://gigazine.net/index.php?/news/comments/20070120_munin_config/
そんな前置きは当たり前として。Fedora11では直ぐに設定できますねぇ
共有ディレクトリ所有者変更(なぜかよく上書きしちゃいます^^;)
#chown -R munin:munin /var/www/html/munin/
smartctlが入っていて次ぎのコマンドが動けば下準備はOKっす。
# smartctl –all /dev/sda
smartctl version 5.38 [i386-redhat-linux-gnu] Copyright (C) 2002-8 Bruce Allen
Home page is http://smartmontools.sourceforge.net/
=== START OF INFORMATION SECTION ===
Model Family: Hitachi Deskstar T7K500
Device Model: Hitachi HDT725050VLA360
Serial Number: XXXXXXXXXXXXXX
Firmware Version: XXXXXXXX
User Capacity: 500,106,780,160 bytes
Device is: In smartctl database [for details use: -P show]
ATA Version is: 7
ATA Standard is: ATA/ATAPI-7 T13 1532D revision 1
Local Time is: Sat Jul 18 18:10:22 2009 JST
SMART support is: Available – device has SMART capability.
SMART support is: Enabled
=== START OF READ SMART DATA SECTION ===
SMART overall-health self-assessment test result: PASSED
General SMART Values:
Offline data collection status: (0x00) Offline data collection activity
was never started.
Auto Offline Data Collection: Disabled.
Self-test execution status: ( 0) The previous self-test routine completed
without error or no self-test has ever
been run.
Total time to complete Offline
data collection: (8389) seconds.
Offline data collection
capabilities: (0x5b) SMART execute Offline immediate.
Auto Offline data collection on/off support.
Suspend Offline collection upon new
command.
Offline surface scan supported.
Self-test supported.
No Conveyance Self-test supported.
Selective Self-test supported.
SMART capabilities: (0x0003) Saves SMART data before entering
power-saving mode.
Supports SMART auto save timer.
Error logging capability: (0x01) Error logging supported.
General Purpose Logging supported.
Short self-test routine
recommended polling time: ( 1) minutes.
Extended self-test routine
recommended polling time: ( 140) minutes.
SCT capabilities: (0x003f) SCT Status supported.
SCT Feature Control supported.
SCT Data Table supported.
SMART Attributes Data Structure revision number: 16
Vendor Specific SMART Attributes with Thresholds:
ID# ATTRIBUTE_NAME FLAG VALUE WORST THRESH TYPE UPDATED WHEN_FAILED RAW_VALUE
1 Raw_Read_Error_Rate 0x000b 100 100 016 Pre-fail Always – 0
2 Throughput_Performance 0x0005 100 100 050 Pre-fail Offline – 0
3 Spin_Up_Time 0x0007 106 106 024 Pre-fail Always – 469 (Average 472)
4 Start_Stop_Count 0x0012 100 100 000 Old_age Always – 770
5 Reallocated_Sector_Ct 0x0033 100 100 005 Pre-fail Always – 0
7 Seek_Error_Rate 0x000b 100 100 067 Pre-fail Always – 0
8 Seek_Time_Performance 0x0005 100 100 020 Pre-fail Offline – 0
9 Power_On_Hours 0x0012 100 100 000 Old_age Always – 6332
10 Spin_Retry_Count 0x0013 100 100 060 Pre-fail Always – 0
12 Power_Cycle_Count 0x0032 100 100 000 Old_age Always – 645
192 Power-Off_Retract_Count 0x0032 100 100 000 Old_age Always – 1006
193 Load_Cycle_Count 0x0012 100 100 000 Old_age Always – 1006
194 Temperature_Celsius 0x0002 162 162 000 Old_age Always – 37 (Lifetime Min/Max 11/54)
196 Reallocated_Event_Count 0x0032 100 100 000 Old_age Always – 0
197 Current_Pending_Sector 0x0022 100 100 000 Old_age Always – 0
198 Offline_Uncorrectable 0x0008 100 100 000 Old_age Offline – 0
199 UDMA_CRC_Error_Count 0x000a 200 253 000 Old_age Always – 0
SMART Error Log Version: 1
No Errors Logged
SMART Self-test log structure revision number 1
No self-tests have been logged. [To run self-tests, use: smartctl -t]
SMART Selective self-test log data structure revision number 1
SPAN MIN_LBA MAX_LBA CURRENT_TEST_STATUS
1 0 0 Not_testing
2 0 0 Not_testing
3 0 0 Not_testing
4 0 0 Not_testing
5 0 0 Not_testing
Selective self-test flags (0x0):
After scanning selected spans, do NOT read-scan remainder of disk.
If Selective self-test is pending on power-up, resume after 0 minute delay.
こんな感じで出ます。
Hitachi Deskstar T7K500 HDT725050VLA360194
Temperature_Celsius 37

これがわかれば今回はOK^^
では設定。
# vim /etc/munin/plugin-conf.d/munin-node
追加
[hddtemp_smartctl]
user root
env.smartctl /usr/sbin/smartctl
env.drives sda
env.type_sda 3ware,0
env.args_sda –all -d ata

プラグインにパスを通す(あえて書けば In~ は1行で(^◇^;)
ln -s /usr/share/munin/plugins/hddtemp_smartctl /etc/munin/plugins/hddtemp_smartctl
/etc/init.d/munin-node restart

後はまったり更新を待つ・・・
「localhost :: hddtemp_smartctl」の項目は追加されているのに値が取得できてないみたいですねぇf(^^;)
ググって見るとSATA接続はデフォルトでこけるらしい(^◇^;
SATA接続のHDD温度をグラフ化する with Munin
http://www.infinity-number.net/archives/1081
先人の知恵は有効に使おうヽ(*^。^*)ノ
変更してみる。(Poderosaなどでコピペすると[’]などが文字化けするんで適宜修正)
vim /etc/munin/plugins/hddtemp_smartctl変更箇所 # On Linux, we know how to enumerate ide drives. SCSI is not as easy
# if (-d ‘/proc/ide’) {
# opendir(IDE, ‘/proc/ide’);
# @drives = grep /hd[a-z]/, readdir IDE;
# closedir(IDE);
# }
if (-d ‘/sys/block‘){
opendir(IDE, ‘/sys/block‘);
@drives = grep /[h|s]d[a-z]/, readdir IDE;
closedir(IDE);
}

リスタートして様子見
# /etc/init.d/munin-node restart
Stopping Munin Node agents: [ OK ]
Starting Munin Node: [ OK ]

まだだめぽ(^◇^;設定を戻す。次ぎの先人の知恵を借りようw


最終的に

[/etc/munin/plugin-conf.d/munin-node]の修正はなし。
■[debian][munin]munin で SATA の温度を見る 02:55 を参考に
http://d.hatena.ne.jp/paraches/20080921/1222019727
# vim /etc/munin/plugin-conf.d/hddtemp_smartctl追加
[hddtemp_smartctl]
user root
env.drives sda
env.type_sda ata

リスタートして後はじっと我慢の子。・・・だめぽ。
うちの環境ではやはりプラグインも少し修正が必要らしい。
vim /etc/munin/plugins/hddtemp_smartctl変更箇所# On Linux, we know how to enumerate ide drives. SCSI is not as easy
if (-d ‘/proc/ide’) {
opendir(IDE, ‘/proc/ide’);
@drives = grep /[h|s]d[a-z]/, readdir IDE;
closedir(IDE);
}
で、今日の迷走も、めでたしめでたし(^^)

Fedora10[ep16] vimの文字化け解消(/etc/vimrcの設定変更)

Fedora11に浮気して、再び再インストールして続きから(^◇^;
ここだけの話・・・[/etc/vimrc]にたどり着くまで小一時間(^◇^;
先にぐぐったのがまずかったw
未熟者には[~/.vimrc]ってどこだろうとwhereisにGrepかけて瞑想してましたf(^^;)
単発で文字コードを直接指定したい場合
(euc-jp)# vim “+e ++enc=euc-jp (ファイル名)”(siftJIS)$ vim “+e ++enc=cp932 (ファイル名)”
自動判別にeuc-jpなどを追加したい場合
# vim /etc/vimrcとして
set encoding=utf8
set fileencodings=iso-2022-jp,sjis,euc-jp
を最後に追加。
おまけ 現在の文字コードを表示する。
# printenv | grep LANG
LANG=ja_JP.UTF-8
(Fedora11の標準設定っす)

Fedora11[ep03] いろいろサービスを止めてみた(^◇^;

このあたりから設定が少しずつ変わってくる感じ。
でも、今回でテストは一時中断。
lm_sensorsがなおるまでFedora11は放置です。
Fedora9の時もそうだったけど、どうも奇数版とは相性が悪いうちの環境っす(^◇^;
Fedora 11初期設定
http://fedorasrv.com/fedora11-init.shtml
SSHサーバー構築(OpenSSH)
http://fedorasrv.com/openssh.shtml
φ(__)m メモメモ….Poderosaで公開キーを作成する時は改行されてペーストされる場合があるので[ssh-dss ~]は必ず1行になるようにする事。(例:nano使用の場合。最後の改行もないほうが確実)
ファイアウォール構築(iptables)
http://fedorasrv.com/iptables.shtml
ここでミスるとSSHで入れなくなるw 当たり前ですけど、rebootできるようにしておきましょう^^;
ほとんどコピペでいけます。動く事が確認できたら必要な設定以外コメントアウトしてポートは閉じておきましょう^^;
Webサーバー構築(Apache)
http://fedorasrv.com/apache.shtml
とりあえず標準的な設定をして、外から見れるようにしておく。
SSIなどはIPTABLEで弾いてあるので設定しない。
RRDToolも使ってみたいのでインストールしてみましょヽ(*^。^*)ノ
# yum -y install rrdtoo
# yum -y install munin
# yum -y install munin-node
RRDToolとMuninをインスコ。設定していきましょう。
# vim /etc/munin/munin.conf出力先設定の<htmldir>を書き換える。
# chown munin:munin /var/www/html/munin/デフォルトのまま行ってみよう^^;
# /etc/init.d/munin-node startで、実行と。
で、apacheを起動して外からの確認と。
動作自体は問題なさそう。問題はセンサーでf(^^;)
ログンイン画面で放置しておくとauditd系のメッセージ。
元を根絶すればいいんだけど・・・停止!ってなわけで。
サービス停止項目。
auditd
 audit に引っかかったシステムコールを特定のログファイルに記録する
avahi-daemon
 mDNSを通してネームレゾリューションを提供するデーモン
ip6tables
mdmonitor
 RAID の状態監視サービス
sendmail
atd
netfs
nfslock
rpcgssd
rpcsvcgssd
-環境によって-
bluetooth
kudzu
setroubleshoot
 ログを解析して、SELinuxによるアクセス拒否の解決方法を示してくれるツール
smolt
 ハードウェア プロファイリング技術
などなど
—結果的にこんな感じ?
cpuspeed 0:off 1:on 2:on 3:on 4:on 5:on 6:off
crond 0:off 1:off 2:on 3:on 4:on 5:on 6:off
httpd 0:off 1:off 2:on 3:on 4:on 5:on 6:off
iptables 0:off 1:off 2:on 3:on 4:on 5:on 6:off
irqbalance 0:off 1:off 2:off 3:on 4:on 5:on 6:off
messagebus 0:off 1:off 2:on 3:on 4:on 5:on 6:off
network 0:off 1:off 2:on 3:on 4:on 5:on 6:off
ntpd 0:off 1:off 2:on 3:on 4:on 5:on 6:off
rsyslog 0:off 1:off 2:on 3:on 4:on 5:on 6:off
sshd 0:off 1:off 2:on 3:on 4:on 5:on 6:off
yum-cron 0:off 1:off 2:on 3:on 4:on 5:on 6:off

[root@localhost ~]# chkconfig –list
NetworkManager 0:off 1:off 2:off 3:off 4:off 5:off 6:off
acpid 0:off 1:off 2:off 3:off 4:off 5:off 6:off
atd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
auditd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
avahi-daemon 0:off 1:off 2:off 3:off 4:off 5:off 6:off
cpuspeed 0:off 1:on 2:on 3:on 4:on 5:on 6:off
crond 0:off 1:off 2:on 3:on 4:on 5:on 6:off
cups 0:off 1:off 2:off 3:off 4:off 5:off 6:off
dnsmasq 0:off 1:off 2:off 3:off 4:off 5:off 6:off
haldaemon 0:off 1:off 2:off 3:off 4:off 5:off 6:off
httpd 0:off 1:off 2:on 3:on 4:on 5:on 6:off
ip6tables 0:off 1:off 2:off 3:off 4:off 5:off 6:off
iptables 0:off 1:off 2:on 3:on 4:on 5:on 6:off
irda 0:off 1:off 2:off 3:off 4:off 5:off 6:off
irqbalance 0:off 1:off 2:off 3:on 4:on 5:on 6:off
mdmonitor 0:off 1:off 2:off 3:off 4:off 5:off 6:off
messagebus 0:off 1:off 2:on 3:on 4:on 5:on 6:off
multipathd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
netconsole 0:off 1:off 2:off 3:off 4:off 5:off 6:off
netfs 0:off 1:off 2:off 3:off 4:off 5:off 6:off
netplugd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
network 0:off 1:off 2:on 3:on 4:on 5:on 6:off
nfs 0:off 1:off 2:off 3:off 4:off 5:off 6:off
nfslock 0:off 1:off 2:off 3:off 4:off 5:off 6:off
nscd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
ntpd 0:off 1:off 2:on 3:on 4:on 5:on 6:off
ntpdate 0:off 1:off 2:off 3:off 4:off 5:off 6:off
pcscd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
portreserve 0:off 1:off 2:off 3:off 4:off 5:off 6:off
psacct 0:off 1:off 2:off 3:off 4:off 5:off 6:off
rdisc 0:off 1:off 2:off 3:off 4:off 5:off 6:off
restorecond 0:off 1:off 2:off 3:off 4:off 5:off 6:off
rpcbind 0:off 1:off 2:on 3:on 4:on 5:on 6:off
rpcgssd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
rpcidmapd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
rpcsvcgssd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
rsyslog 0:off 1:off 2:on 3:on 4:on 5:on 6:off
saslauthd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
sendmail 0:off 1:off 2:off 3:off 4:off 5:off 6:off
smartd 0:off 1:off 2:off 3:off 4:off 5:off 6:off
sshd 0:off 1:off 2:on 3:on 4:on 5:on 6:off
udev-post 0:off 1:on 2:off 3:off 4:off 5:off 6:off
wpa_supplicant 0:off 1:off 2:off 3:off 4:off 5:off 6:off
ypbind 0:off 1:off 2:off 3:off 4:off 5:off 6:off
yum-cron 0:off 1:off 2:on 3:on 4:on 5:on 6:off
[root@localhost ~]#


とりあえず動いているので前回の止めすぎで動かなくなった時から反省してめもをとる事に(^◇^;
次ぎからはスクリプト組んで止めちゃうので個別設定する事は減るかなぁと思ってます。
ではFedora11を触ってみた!全3回で中断っす^^;

Fedora11[ep02] ATOM330にlm_sensorsで失敗に・・・(未解決)

lm_sensorsが失敗続きでインストールしなおしてみた訳ですが^^;
なかなか問題児で。
Bug 496355 – lm_sensors crippled in fedora 11 beta
https://bugzilla.redhat.com/show_bug.cgi?id=496355
こやつかと思ったんですけどねぇ
it87xxチップは/etc/grub.confに以下を追加で回避できるそうな・・・
acpi_enforce_resources=lax
困った・・・(^◇^;
解決できないと笑い話にもならないw
やはり半年待つべきか!

Fedora11[ep01] ATOM330にインストール!(最初はyumのエラーを直そう)

ATOM330にFedora11をインストール!の巻
思いっきり何かを吹き飛ばしたようなリスタート(^◇^;
さてと・・・はじまりはじまりっと。
Fedoraで自宅サーバー構築
http://fedorasrv.com/
Fedora 11インストール
http://fedorasrv.com/fedora11.shtml
ファイルフォーマットはデフォルトでext4になってるあたりがミーハーハードマニアとしてはうれしい(^^)
前回の苦労はどこにww
いつものように参考ページを元にさくさく設定
フォントが小さくなって画面が1024x768フルに使えていい感じヽ(*^。^*)ノ
「Fedoraで自宅サーバー構築」さんの設定では569パッケージのインストール。
ネットワーク設定をして再起動。
で、
# yum -y update yumと接続テスト。
Error: Cannot retrieve repository metadata (repomd.xml) for repository: updates. Please verify its path and try againむむむむ。
さて直すとするか(^◇^;(場合によっては/etc/resolv.confに[nameserver 192.168.0.1]とか必要かも)
/etc/yum.repos.d/fedora.repo
/etc/yum.repos.d/fedora-updates.repo
の2ファイルの中の「baseurl」をコメント(#)をはずして有効、「mirror」設定をコメントアウト(#付加)。本家のアドレスにじかに行きますが、あとでfastestmirror入れるのでよしとしておこうw
baseurl=http://download.fedora.redhat.com/…
#mirrorlist=http://mirrors.fedoraproject.org/…
とかとか
# yum -y update yum
# yum -y install yum-fastestmirror
# yum -y update fedora-release
# yum -y update
2009/06/29現在 最後のupdateはDownload154Mの88filesとなってます。展開後173ファイルのインストール。
2009/07/02現在 最後のupdateはDownload156Mの4パッケージ90filesとなってます。
Fedoraの最新版は結構アップデートがあるのでこまめにチェックが必要です。(184files)
yum-cronにすべて任せたいところですがf(^^;)
おろ・・・
JBD: barrier-based sync failed on dm-3:8-disabling barriers設定をこなしているとなにやらメッセージが来た。RAIDなどで整合性が取れないような時に出るメッセージらしい。組んでない時はスルーでよさそう(いいのかそれで^^;)